Loading...
03-05-01 PC Agenda AGENDA GOLDEN VALLEY PLANNING COMMISSION Regular Meeting Golden Valley City Hall, 7800 Golden Valley Road Council Chambers Monday, March 5,2001 7:00 P.M. I. Informal Public Hearing -- Preliminary Design Plan - Lions Park P.U.D. No. 92 Applicant: Lions Park Development, LLC Address: 7001 Harold Avenue, Golden Valley, MN Purpose: The P.U.D. would allow for the construction of 6 single family homes on new lots II. Informal Public Hearing - Property Rezoning (Z020-01) Applicant: Susan Gonyea Address: Lots 9, 10 & 11, Block 8 of Lakeview Heights located at 9120 Plymouth Avenue North, Golden Valley, MN Purpose: The applicant is requesting a rezoning of a portion of the property from Residential to Two-Family (R-2) Residential -- Short Recess -- III. Reports on Meetings of the Housing and Redevelopment Authority, City Council, Board of Zoning App.eals and. other Meetings IV. Other Business A. Discuss new Commission Guidelines B. Discuss GTS Land Use Planning Workshops V. Adjournment . . . " Memorandum Planning 763-593-8095/763-593-8109 (fax) Hey To: Golden Valley Planning Commission From: Dan Olson, City Planner Subject: Informal Public Hearing - Preliminary Design Plan for Lions Park Addition, P.U.D. No. 92, 7001 Harold Avenue - Lions Park Development, LLC, Applicant Date: February 28, 2001 Background This Planned Unit Development (PUD) Preliminary Design Plan is the first step by the applicant to gain approval in order to achieve the goal of establishing a PUD for the construction of six new single family homes. A location map is attached showing the location of the proposed PUD. ThePUD process will now begin to establish the exact requirements under which the development would be built and operated. There are two stages of approval for a PUD proposal. This is the first, or the Preliminary Design Plan stage. The purpose of this stage is two-fold: to give broad concept approval to the proposal and to call out issues that must be addressed in detail as the proposal moves ahead to the General Plan of Development stage. Preliminary Plan approval does not guarantee that a proposal will become reality. It gives the applicant some assurance of being on the right track, and some guidance in how to proceed. In the case of the Planning Commission, in particular, the limitations of Preliminary Plan approval are clearly laid out. City Code Sec. 11.55, 6.D provides that: The Planning Commission's consideration of the application shall be limited to a determination of whether the application constitutes an appropriate land use under the general principals and standards adhered to in the City and, if necessary, its report shall include recommended changes in the land use planned by the applicant so as to conform the application or recommend approval subject to certain conditions or modifications. Summary of Proposal Lions Park Development is requesting a PUD for a development that contains 6 new single family homes. The overall development is 56, 313 square feet (1.29 acres). The existing lot is actually 61,269 square feet in size ( 1.4 acres), but the City is taking 10 feet to increase the right of way along Louisiana Avenue. The overall density of the development is less than 5 units per acre. It is located between Harold Avenue and Kentucky Avenue, east of Lions Park. Attached is a copy of the site plans. The 6 new single family homes would be located on new lots that would have access from existing Louisiana A venue. Each home would be a traditional two-story design with full basements. The homes would each be priced between $450,000 and $600,000. The applicant has attached a narrative giving a more complete description of the proposed homes. A homeowner's association is not being proposed. The applicant held a neighborhood meeting on January 24th to present his proposal for this property. Notices for this meeting were sent to property owners within 500 feet of the site. At this meeting, the applicant originally proposed building 10 single family homes. This number was reduced to 6 homes after hearing the comments from those attending the meeting. Louisiana Avenue, which separates this lot from Lions Park, currently has a 30-foot right of way width. Because this right of way width does not meet the width recommended by the City Engineer, the City will take an additional 10 feet of property from this property to increase the Louisiana Avenue right of way width to 40 feet. As you can see from the site plans, the applicant has dedicated an additional 20 feet of right of way along Louisiana Avenue for this development. This was done at the initial request of the City Engineer. However, after reviewing the site plans, the Engineer is now recommending that only an additional 10 feet of right is needed. Also, according to the City Engineer, it has not yet been determined how the applicant will pay for the improvements to Louisiana Avenue. Because of the size of the lot, the City Engineer has stated that a storm water retention pond is not required. Eligibility of Application City Code Section 11.55 regulates PUD's. Four subdivisions of Sec. 11.55 come into play when screening PUD applications for eligibility. Staff has reviewed these eligibility requirements and found that the proposed development qualifies as a PUD. Therefore, the proposal may enter the preliminary design phase. P UD Definition This development clearly meets the terms ofSubd. 2 (A)(5) that "developments having two or more principal use structures located on two or more lots in single or multiple ownership, provided the combined area totals one or more acres and the plan submitted includes the entire area to which the planned unit will apply". P UD Purpose and Intent Applications must also meet the general purpose and intent ofPUD's in Golden Valley as set out in Section 11.55 Subd. 1. Staff believes the purpose and intent have been met. Lions Park Development is proposing a PUD for this site because the PUD offers "an optional method of land use regulations which permit design flexibility by substantial variances from the provisions of the Zoning Code, including uses, setbacks, height, parking requirements and similar regulations". Standards and Criteria for P UD 's City Code establishes basic requirements for different types ofPUD's in Sec. 11.55, Subd. 5. Residential uses are discussed in Subd. 5(B). Although only apartment developments fall into this category, the City has consistently applied the established standards and criteria to all residential PUD applications. There are eight items covered under the basic standards for residential PUD' s. Staff will comment on each of the eight items: 2 " . . . . . . 1. All residential PUD' s must have at least 100 feet of frontage on a public street. This development has over 495 feet of frontage on Louisiana Avenue. 2. Public sewer and water must serve all developments. Fire hydrants must be installed according to a plan approved by City staff. Please refer to the attached memo from City Engineer Jeff Oliver, PE dated March 1,2001. No principal building in the PUD can be located closer than the measurement of its own height to a rear or side property line when such line abuts a single-family use. Its is Staffs opinion that this criterion was developed for apartment buildings that are much taller than single family homes and therefore is not applicable to this development. 3. Private roadways within the PUD must be constructed according to a plan and approved by the City Engineer. There are no private roadways in this development. The access road to the six single family homes is an existing public street. 4. No building within the PUD may be located closer than 15 feet from the back ofthe curb along any internal roadway. This requirement is met for each of the housing units in the PUD. 5. Provisions for solid waste storage and disposal must be in accordance with a plan approved by the City. In this case, each of the single family owners would be responsible for solid waste disposal similar to other single family developments in Golden Valley. The public street insures that garbage and recycling vehicles have adequate access. 6. Landscaping must be in accordance with a detailed planting plan approved by the City, and must meet the established minimum landscape standards for this type of development. The landscape plan has not been submitted as part of the Preliminary Plan. This will be done as part of the General Plan submittal. This plan will include a tree preservation plan as required by City Code. 7. Shared land, buildings, or infrastructure must be either dedicated to the public, placed under landlord's control, or regulated through a homeowner's association. The applicant for this PUD is not proposing any shared facilities. Completeness of Application Packet Staff has determined that the packet and application submitted by Lions Park Development is complete. Planning Considerations The types of issues that come up in connection with PUD applications can vary based on the PUD type and on specific characteristics of each PUD. In this case, staff has identified no particular concerns beyond those that generally accompany residential PUD's. They can be grouped into the categories of zoning trade-offs, park dedication, Livable Communities, and miscellaneous engineering/constructions issues. Each category will be addressed in the following paragraphs: Zoninf! The "Purpose and Intent" paragraph of the City's PUD requirements make it clear that a major intent of the PUD process is to "permit design flexibility by substantial variances from the provisions of the zoning chapter, including uses, setback, height, parking requirements, and similar regulations." Thus, to some extent, variances are a given with any PUD request. 3 Despite the basic intent of the PUD process with regard to variances, the City must ensure that each proposal does not exceed the bounds of good design practices in the type and extent of variances being . requested. To that extent, it is useful to have an understanding of how any proposal varies from the normal zoning standards. The standards to use for comparison for the single family homes in the Lions Park proposal are those of the Residential zoning district. After reviewing the proposal, staffhas found that there are several variances for the six single family homes. The Residential zoning district requires that all lots for single family homes be at least 10,000 square feet in area and be at least 80 feet wide at the front setback line. In addition, according to City Code Section 12.20, Subd. 5 (B), comer lots shall be platted with a width of 100 feet. There are two comer lots in the Lions Park PUD. None of the six lots meet the area requirement. In addition, none of the lots meet the 80- foot width requirement (they are instead 77 feet wide). The two comer lots do not meet the 100-foot width requirement (they are instead 93.5 wide) None of the single family homes meet the 35-foot front yard setback requirement. These front setbacks are instead 30 feet. The two comer lots also do not meet the 35-foot comer yard setback requirement. These corner yard setbacks are instead also 30 feet. The rear yard setback requirement is 20% oflot depth (therefore 24.7 feet), and all of the lots meet this setback requirement. The side yard setback requirements are 15 percent of the lot width.. For the four interior lots, this requirement is 11.5 feet and for the two comer lots this requirement is 14 feet. The four interior lots meet these side yard requirements, while the two comer lots do not. Park Dedication As a residential development, the Lions Park Development is subject to the City's park dedication . requirement of land or its equivalent cash value. The plans show no land reserved for a public park within the development. The staff has forwarded these plans on to the Park and Recreation Department for their review and recommendation regarding park dedication. Livable Communities Golden Valley, like most other metro area cities, has made a commitment to contribute its best efforts toward increasing the supply of affordable and life cycle housing by participating in the Livable Communities program created by state Jaw. As part of its commitment, the City adopted a policy of including a Livable Communities impact evaluation in the consideration of any proposed housing development. Staff has found that the proposed development has a positive impact on one ofthe four Livable Communities measurements. The proposed development is all owner occupied so the percentage of owner-occupied units in Golden will increase with this development. The theory is that rental units usually provide lower cost housing units and another housing opportunity for those who do not wish to own. Because the Lions Park development is low density (5 units per acre) the development would not significantly alter the City's overall housing density. With increased housing density, more affordable housing opportunities are usually created. The Lions Park development would not enhance ownership affordability because the homes are to be priced over $450,000. The Livable Communities standard for owner-occupied affordabilityis about $135,000. . 4 . En~ineerirz~/Construction Issues Comments from the Public Works and Inspections Department are attached. Since specific construction details generally do not come up until quite late in the development process, the comments of the Inspections Department are brief. Traffic The six single family homes to be constructed on the existing street would generate about 60 trips per day. The existing local street system has the capacity to handle these additional trips. About 20% of the 60 trips would occur in the AM and PM peak hour. 1. 2. 3. . 4. 5. Staff Recommendations Staff recommends approval of the Preliminary Design Plan for Lions Park Addition, PUD No. 92. The proposed 6-unit development would provide additional single family homes that are needed in Golden Valley. The staff has met several times with the applicant and the applicant has also met with the surrounding neighborhood. The recommended approval is subject to the following recommendations: Any park dedication recommendation the Planning Commission deems appropriate. The recommendations of City Engineer Jeff Oliver as found in his memo dated March 1, 2001 become a part of this approval. Determination regarding the dedication of additional right-of-way for Louisiana Avenue as may be requested by Hennepin County. The notation of"P.U.D. No. 92" shall be made a part of the plat name. Proof of recording for the plat must be provided to the City before any construction permits are issued. Attachments: Location Map Narrative from the Applicant Memo from City Engineer Jeff Oliver dated March 1,2001 Oversized Site Plans (3) . 5 . . . .. THEIIEFFER CIMPANIES,llC 8815 West 34th Street - S1. Louis Park, MN 55426 Phone 952-897-0848 - Fax 952-897-0309 02/05/01 Attn: Mark Grimes - Director of Planning & Development City of Golden Valley 7800 Golden Valley Road Golden Valley, MN 55427 Re: (PUD) application for 7001 Harold Ave Sec. 11.55 Subd.1,2,5,6,13C-E,13.K , Dear Mark, Sec. 11.55 Subd.l It gives. Il1e.great pleasure to ptesenttoyou and the City of Golden Valley my(PUD) application of 6 single fatnily housing lots to be located on the. East side of Louisiana Avenue North, just North of Kentucky Ave. and just South of Harold Ave. The current address of this site is 7001 Harold Ave... As you know, the owner 8' occupant~ 1 st Aposotolic Lutheran .church is moving to a new location in.Medina, MN.Whilethe current zoning is institutional and most of the land has been used forchl.lfch parking. .This is a.wonderful.location for new single family homes. As you also know, I have. had ameetingwith the neighborhood(Jan 24th, 2001) I felt that this meeting was verypositive in nature and the feelings of the homeowners are well reflected in this (PUD) application. (see attached letters of support) The overall view and feeling was to have less housing from originalconceptplan~ while having higher values for the new home being constructed. In short thisplanthatI am submitting is very much inlinewiththe City of Golden Valley's standard lots,. <. What!.arn asking for is 77' wide center lots (4) and96' comer lots (2). These small 3' & 4' (totalingsome 20') variances will allow for a.sixth home. site. With.the shortness ofgoodbuildableJand~(inanycity) I feel that this is a small change to make for the sixth homesite. Ihavekeptthe.side yard setback at .15(% of width oflot.{insteadof12' it's 11.55") This will allow fora home 54'wide on center lots. The comer andfront setbacks are being requested at 30' insteadoff5'. .As you know the City of Golden Valley willbe taking the frrst20'from our propertyaspartofa new "Proposedright-of-\Vay".Thiswill then leave me with a lot about 103..7 deep~Jess a home depth of (ballpark) 43' =30' deep back yard (25' is min.) Granting the comer setbacks will allow a 52' wide homeys. a 47'lTIax. Front dooraccess & front .elevations. for.all homes will be on Louisiana Ave.~ both comer.lotsc()uld have option for side load garage access off Kentucky or Harold Ave.'s. Sec. 11.55 Subd.2 This proposal.meet definition #5. ..Tlris property will have more. than two home structures. (6) and they will be built on two orwore lots with single ownership of each lot. The priginallot size is more than one acre and the Wll lot is being submitted for redevelopment. Sec. 1155 Subd5 Standards & Criteria for PUD Permit..Residential The site location for this PUD is the Northeast comer of Lions Park in Golden Valley, MN. The location is a beautiful location with a full city park just across the street. This park is used on full time basis and has may play fields, tennis courts, playgrounds & picnic areas. My intention is to create six new single family homesites that are in harmony with this open space and will playoff the wonderful views vs shut them out. The housing that I see for this block is one of open floor plans, homes that have first floor laundry with mudrooms for the kids. Homes that have an option to have a masterbedroom suite on the main level with other levels housing the grandkids etc. The homes will be single family in nature and they each will be responsible all normal day to day up keep. ie; garbage, snow & grass. The homesite will be approx. ' 1,800-2,000 square feet on the main level with additional footage up or down. The basements will be full basements with.daylightJegress windows and they will be draintiled. The homesites will be hooked up to city water and sewer and a fire hydrant will be located and placed if found necessary. The height of pricinple buildings will be of code and will comply with the City of Golden Valley. I do not have any private roadways on this proposed site. Each homesite will be give a landscape allowance of $500 to be spent on the front of the home first.(grass,trees etc.) I ampround to saythatmy goal is to save some 11-12 trees out of the 15 currently on site. (see plan) Sec. 11.55 Subd.6 Application Procedure... A smaller number of copies of the preliminary design plan has been submitted for your viewing, please contact myself or Tom Veenker of All-Metro Development consultants at 763-566-3487. We will make the. additional copies upon your request and. drop them off asap. . As stated by the application procedure, you will create and contact the 500' list of property owners that sWTound the proposed homesites.. I also have included the filing fee of $250.00. Variance request: Comer lots from 100' wide to 9353 wide Center lots from 80' wide to 77.06 wide Front setbacks from 35' deep to 30'deep Sideyard setbacks from 12' to 11.55 Comer lotsideyardsetback from 35' to 30' Mark, I would like tothankyouand Dan very Inuchfor your help and Comments during this process. You both have. bee.n wonderful to work with. I truly believe that this plan is one of quality & respect to the City of Golden Valley, its parks & the surrounding neighbors... This single family development will also bring some. $30,000 per year to Hennepin County and the City of Golden Valley in homestead taxes Vs current Non-Pr()fit status.. Also a park fee of $7,500 will be paid directly to the City of Golden Valley~ lhavealso contacted Ed Anderson from the City of Golden Valley Fire Department, he is very ~terested in using thechurchfora numberofpracticedrill(non-buring) before. the church is brought down,. I feel this isagreat idea and hope that this city feelsthe same. Feel free to giyerne a call if you have any questions or concerns. - . . . I 1 \ . . . Memorandum Public Works 763-593-8030 I 763-593-3988 (fax) t, alley Date: March 1, 2001 To: Mark Grimes, Director of Planning and Development From: Jeff Oliver, PE City Engineer H Subject: Preliminary Design Plan Revi.ew for Lions Park Addition Planned Unit Development Public Works staff has reviewed the plans submitted for a proposed Planned Unit Development to be called Lions Park Addition. The proposed development consists of six single family lots and is located east of Louisiana Avenue North, north of Kentucky Avenue North and south of Harold Avenue. Lions Park is located immediately west, across Louisiana Avenue North, of the proposed development. Preliminary Plat: Louisiana Avenue North currently has 30 feet of street right-of-way dedicated adjacent to this property. The existing 30 feet of right-of-way was dedicated when the Western Avenue Park Addition, the underlying plat that is now Lions Park, was platted. If the required 30 feet of street right-of-way had been acquired across the property currently being developed it would have required removal of the former church building that still stands on the site. The eastern half of the existing Louisiana Avenue roadway currently sits within the existing street right-of-way. The western half of Louisiana Avenue is within property that is now Lions Park, although it is not within dedicated right-of-way. Preliminary discussions with the developer included a dedication of an additional 20 feet of right-of- way dedication for Louisiana Avenue, as shown on the preliminary plat. However, upon further review, and consideration of the City of Golden Valley Pavement Management Policy, it is unlikely that the alignment of Louisiana Avenue would be varied greatly at the time of street reconstruction in order to preserve significant trees located on the property being developed. However, the need for additional right-of-way, primarily for the future location of underground utilities, is still a concern. Based upon the above concerns, staff is recommending a reduced right-of-way dedication to ten additional feet on the east side of Louisiana Avenue. However, in order to provide adequate space for future utility needs staff is also recommending that the standard ten foot wide drainage and utility easement along streets be increased to 20 feet. These dedications will provide a total of 30 additional feet on the east side of the roadway for future street and utility needs. The revised dedication requirements will also result in larger lots, and the ability to move the proposed homes closer to the street, which will increase the separation with homes to the east and result in larger backyard areas for this development. Reconstruction of the local streets in the vicinity of this development as part of the pavement management program is tentatively planned for 2003. Staff is recommending that the developer escrow with this development for the future special assessments against these proposed lots, which would eliminate any special assessments at the time of street rehabilitation. Based upon the City of Golden Valley Special Assessment Policy the total assessment for these lots would be $14,400 at the 2001 assessment rates. Therefore, the developer should pay this amount as part of the development approval. There is an existing five foot wide concrete sidewalk on the south side of Harold Avenue adjacent to this property. There are no additional sidewalks or trails identified in the City planning documents within this development. The proposed driveway locations for these homes are acceptable as shown on the plans. The homebuilders will be required to obtain a right-of-way permit for each of the proposed driveways prior to installation. Gradina and Utilitv Plan: This proposed development is located within the Sweeney Lake subdistrict of the Bassett Creek Watershed and is subject to the Water Quality Policy. According to thepolicy, a residential development larger than 2.0 acres is required to provide water quality ponding. This proposed project is 1.41 acres in size, so the developer does not need to provide water quality ponding. However, the developer is required to prepare an erosion and sediment control plan and implement best management practices as needed for this project. The following information must be included on the grading plan that was submitted for review: f I . 1. If the site is to be mass graded a construction entrance must be designated and shown on the plan. A gravel construction entrance must be installed at this entrance, and the standard detail plate for the gravel entrance must also be included. . 2. The standard detail plate for silt fence installation must be included on the plans. 3. Erosion control notes must be included on the plan that includes information on site stabilization following grading and sweeping of adjacent streets. This development is subject to the City of Golden Valley Grading, Drainage and Erosion Control Ordinance. As outlined in the ordinance, a permit is required for mass grading of the site and individual permits will be required during construction of the homes. No grading or earth disturbing activities are to occur on site until the appropriate permit has been obtained from the Public Works Department. This proposed development will not require the installation of sanitary sewer or watermain extensions to provide service. Each home will be required to install new sewer and water services as shown on the plans. This work will require sewer and water permits, and a right-of-way permit prior to installation. Tree Preservation: This development is subject to the City of Golden Valley Tree Preservation Ordinance. Therefore, the developer must submitted a Tree Preservation Plan prepared to City standards as part of the General Plan submittal for the development. G:\Developments-Private\Lions Park Addition\Prelim Design Review.doc . it \ . . . Summary and Recommendations: Public Works staff recommends approval of the Preliminary Design Plan for the Lions Parks Addition Planned Unit Development subject to the following conditions: 1. The final plat includes dedication of ten feet of street right-of-way on Louisiana Avenue North, and a 20 foot wide front yard drainage and utility easement, as outlined in this report. 2. The developer post a $14,400 escrow for street reconstruction, which is tentatively planned for 2003 as part of the pavement management program. 3. A Tree Preservation Plan must be submitted as part of the General Plan application. 4. Subject to the comments of other City staff. Please feel free to call me if you have any questions regarding this matter. C: Jeannine Clancy, Director of Public Works Mark Kuhnly, Chief of Fire and Inspections AI Lundstrom, Environmental Coordinator Gary Johnson, Building Official Dan Olsdn, City Planner Ed Anderson, Deputy Fire Marshall G:\Developments-Private\Lions Park Addition\Prelim Design Review.doc . . . Hey Planning 763-593-8095/763-593-8109 (fax) To: Planning Commission From: Mark Grimes, Director of Planning and Development Subject: Zoning Map Amendment (Rezoning) of West % of Lots 9,10, and 11, Block 8, Lakeview Heights (9120 Plymouth Ave. N.) from Residential to Two-Family Residential (R-2)-Susan Gonyea, Applicant Date: February 27, 2001 Susan Gonyea is requesting a change in the official zoning map for a portion of the property she owns at 9120 Plymouth Ave. N. in Golden Valley. Her request is to change the zoning of the west half of her property from Residential (single-family) to Two- Family Residential (R-2). At the current time, the entire property is zoned Residential. The rezoning is requested because Ms. Gonyea has applied for a subdivision (consolidation) of her properties into two lots. The new west lot would be for the existing two-family home and the east lot would be for a new single family home. In order for the subdivision to be considered by the City, the lots in a subdivision or consolidation must meet all requirements of the zoning code. In this case, all requirements of the zoning code are not met for the west lot because a two-family home is located in the Residential-zoning district. Two-family homes are only permitted in the Two-Family (R-2) zoning district. The two-family home at 9120 Plymouth Ave. N. was constructed in 1964. At that time, two-family homes were considered permitted uses in the Residential-zoning district if certain lot area requirements were met. In the early 1980's, the City's zoning code was changed to permit two-family homes only in a new, Two-Family Residential zoning district. Therefore, all existing two-family homes became non-conforming at that time. The only way to get rid of the non-conforming status is to rezone the property to Two-Family Residential. The Two-Family Residential zoning district requires that lots be at least 12,500 sq. ft. in area. The setback requirements are 15 ft. on the side and 20% of the lot depth for rear setback. There must also be a garage for at least two cars. In the case of the Gonyea lot that is proposed to be rezoned to Two-Family Residential, the lot.meets or exceeds these requirements. The Comprehensive Plan Map designates this area for Low Density Residential (0-5 units per acre). This type of two-family home is consistent with this Low Density designation. Overall, the density of this residential area north of Plymouth Ave. between TH 169 and the James Ford Bell Research Center is far less than 5 units per acre. Immediately to the west of the Gonyea two-family home (Gettysburg and Plymouth) is another two-family home that is also zoned Residential. This two-family home was also constructed prior to 1980 and is now, therefore, non-conforming. This property is not proposed for rezoning. The property to the east is zoned Industrial and occupied by the General Mills James Ford Bell Research Center. This area is designated on the Comprehensive Plan for Industrial uses. The . properties to the south are zoned Light Industrial and designated on the Comprehensive Plan for Industrial uses. Recommended Action The zoning code section on Zoning Map Changes (Sec. 11.90, Subd. 3) gives no specific requirements for information that must be submitted or analyzed as part of a zoning map amendment application. Other than conformity with the Comprehensive Plan map, there is much discretion given to the City when considering rezoning requests. In this case, the staff has pointed out that the proposed lot and double home that is on the lot meet or exceeds the requirements for a double home in the R-2 zoning district. The proposed rezoning is also consistent with the comprehensive plan because it would not change the overall low-density character of the neighborhood. The double home has been located on this property since 1964 with no adverse impact on the area. Staff has found no complaints about the double home in any City file. By rezoning the property to R- 2, the City is making the lot and double home conforming with the zoning code and, therefore, enhancing its status. The rezoning will also help the City to maintain additional housing that is more affordable and provide a wider ranger of housing types in the City. The staff is recommending approval of the rezoning of the property from Residential to Two-Family Residential (R-2) with the condition final approval of the rezoning not be released until after the final plat is approved by the City Council and filed with Hennepin County. . . . . z I CITY ---' J' ], J, ~ ---. :r: t- ::> o ~ >- ..J a. -J OF NEW HO' ~~~''- "~(;_"~,,,,~'6",,\ ~\\ ~\ ~\ l'OG anNaL\. v G......... ", _~_-_" '" /-'\-\\--\- \ \ CI.s-__ ' JS~,. ......... "" \ -,-60.0 \. ~ "-. "I 96'Lr \ ': g,--- "---LO'L9- , ",,\, I' \ \ \ \ " --- -... ,<:: 'l't "" [\ ;:1 \ \ \ \ \ \ \ rl~l.!- ;' \.-=.=-- - 't, """ \\ '; (; 1\ 1 \', \\ \, ~ \\ ~ 'I I " "'" ~ '-" '" NIV'\ij31VM -, --- ) >1 \ \ I ",--" tis, '\\ \ t:J. C )11 '\ \ \ I I I I If - - - i \ I , "" \).___ O~, _, \ I I 3sno H I 'f' "'\ V ___~ -~ -J\ J ~ DNI1SIX3 \ ~ '" \ ~\ ... . .. '" I I I \ \ - - J ~ '\ \ q , 1 :;' \ \\J. I ('\ I - (i - br~,- \ ~ \ ,::q._'_ -G' \1 b k)\ v ~ I - ,: '\\ \ ~ ~ t:J. ~; ~I :~~A~--~ r~1\ \ 0 "V" / ~ l e\ \ ~ " ' . S9J6 ~;r.,.. I C-.\ \ Mt,. fry' 77 /71 I ~ I ' \" ..,,~ . o~.' '0 V . '/I e \-\~ t >' , I : [;l~~f:E~ ':,_ '\.O't\ \.~f~:J>'1. ~'v'~ I \11 \. (\ I . , '," , I f ~ ~ I ~ :Ty \.\,~~..t, LL_ -" -\ ' V3ijV 311d >lo.OlS _ _' :: (')!J! q \ \ J . \ .\ \ \ - - ,"\ .., _. _.. ..., I ""l' : . . \ .'. \ 03ZV ij 38 ' I I \ t:J..', 1 I" ' .,~ 01 3:)V!lVD-- , \ I \ ' :: ~ +I'~L I) ..' t -t"\ ',\ '\ , \ \ . \ \ \ ..,.\".; .,,~~J _,.! E oo~ f. ~ \ \ \,~" \ \' I .' %6"w/V~.b.-;j \ 926' r.,' \ I . \ r'\ : " .I \ ',.,.. . . fro_EaSt.. " t" :..I .: ,; ,": I \ 8 " I~ ' ~ '" property e 'I' -. :~ 1 \ " ...,. . : it;; . .', . 'ill . , , , , '--/ \ \' l: i.(~ \ \\--60'OC1- ~.' 16 Lt, {' , \ '," ~., ..\ \ ,\ \ \ ~\"' \. "\-\ \ _____ .... -1l_ I v, 'I r , , \ I I I I, \ \ - - r - - -II i 03~0~3: _ _ \, ~ ~ t :- \ \ I I I (\ \ '\ I I I / 1 ;' ) :::! 1q~~ \\\\\ \ \ \ \;<' I " " ,I / I I /' : 'I ~ r': \ \ \ \ \\' \ \ \ I '--' I / :-j l', \\\ \\\ 1\ 1/ I / I I 1/ 1 ! ~<,," "'..... is: 1 I :- \' \ \ \ \ I \ I (( I I r I I ,-,:- ::1 tf-"~" 4LI_1.~ I I! I 'I 1 80g~t~~ ~ ~ J ~ ~ ..1 j ~ :: T 7 - -r - -t + - - " .~ IV 0 ~ . ~ No &.~ ~ ~ ~ . tJI Ii . ~ ~~ Ol a '1. i I Og